Warm air heater for stable
Gas fired warm air heater for stable heating as fully automatic system with infrared flame monitoring, electrical ignition and supporting air blower and open combustion chamber for operation without exhaust system. The unit can be switched over from one to the other gas type by only changing the nozzle and new setting of pressure.
FEATURES
- Electric mains with shock-proof plug.
- Gas connection ¾“ or ½“ internal screw thread.
- Casing and combustion chamber made of stainless steel.
- Splash-proof switch box.
- Drive via room thermostat or ventilating control possible.
- Automatic ignition.
- Three-point suspension by adequate attachment eyes.
- Clean Combustion (DIN 33697, CO˂0,003%V): Air quality in a stable is our priority.
- Low-maintenance burner.
- For Natural Gas and LPG (except for NG-LE 10)
- Extremely Secure Unit for each kind of animals.
TECHNICAL DATA
The great range COPILOT SOL NGL: always any heater adapt to your stable.
Type of Unit | SOL NG-LE 10 | SOL NG-L 30 | SOL NG-L 50 | SOL NG-L 80 | SOL NG-L 100 |
Nominal Capacity | 10kW | 30kW. | 50kW. | 80kW. | 100kW. |
Air capacity | 500m3/h | 1.600m3/h | 2.300m3/h | 4.100m3/h | 7.500m3/h |
Supply Pressure | 0,02bar | 0,02bar o 0,05bar | 0,02bar o 0,05bar | 0,02bar o 0,05bar | 0,02bar o 0,05bar |
Connected load | – | 2,33 Kg/h | 3,89 Kg/h | 6,23 Kg/h | 7,78 Kg/h |
Category | Natural Gas I2E | Natural Gas and LPG I3 B/P | Natural Gas and LPG I3 B/P | Natural Gas and LPG I3 B/P | Natural Gas and LPG I3 B/P |
Rated Current | 0,3A. | 0,85A. | 1,0A. | 2,9A. | 3,7A. |
Dimensions mm. | 500 x 450 x 450 | 990 x 445 x 312 | 990 x 510 x 365 | 1150 x 560 x 410 | 1250 x 640 x 510 |
Weight | 16kg. | 35kg. | 41kg. | 45kg. | 56kg. |
Electric Supply | 230V / 50Hz. | 230V / 50Hz. | 230V / 50Hz. | 230V / 50Hz. | 230V / 50Hz. |
Throw | 15m. | 30m. | 40m. | 50m. | 60m. |